Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Anal Bioanal Chem ; 413(26): 6503-6511, 2021 Nov.
Article in English | MEDLINE | ID: covidwho-1370381

ABSTRACT

We describe a rapid liquid chromatography/tandem mass spectrometry (LC-MS/MS) method for the direct detection and quantitation of SARS-CoV-2 nucleoprotein in gargle solutions and saliva. The method is based on a multiple-reaction monitoring (MRM) mass spectrometry approach with a total cycle time of 5 min per analysis and allows the detection and accurate quantitation of SARS-CoV-2 nucleoprotein as low as 500 amol/µL. We improved the sample preparation protocol of our recent piloting SARS-CoV-2 LC-MS study regarding sensitivity, reproducibility, and compatibility with a complementary reverse transcriptase quantitative polymerase chain reaction (RT-qPCR) analysis of the same sample. The aim of this work is to promote diagnostic tools that allow identifying and monitoring SARS-CoV-2 infections by LC-MS/MS methods in a routine clinical environment.


Subject(s)
COVID-19 Testing/methods , COVID-19/diagnosis , SARS-CoV-2/isolation & purification , Saliva/virology , Tandem Mass Spectrometry/methods , COVID-19 Testing/economics , Chromatography, Liquid/economics , Chromatography, Liquid/methods , Coronavirus Nucleocapsid Proteins/analysis , Coronavirus Nucleocapsid Proteins/isolation & purification , Humans , Limit of Detection , Phosphoproteins/analysis , Phosphoproteins/isolation & purification , Reproducibility of Results , Specimen Handling , Tandem Mass Spectrometry/economics , Time Factors
2.
J Chromatogr B Analyt Technol Biomed Life Sci ; 1171: 122641, 2021 May 01.
Article in English | MEDLINE | ID: covidwho-1126911

ABSTRACT

Remdesivir, formerly GS-5734, has recently become the first antiviral drug approved by the U.S. Food and Drug Administration (FDA) to treat COVID-19, the disease caused by SARS-CoV-2. Therapeutic dosing and pharmacokinetic studies require a simple, sensitive, and selective validated assay to quantify drug concentrations in clinical samples. Therefore, we developed a rapid and sensitive LC-MS/MS assay for the quantification of remdesivir in human plasma with its deuterium-labeled analog, remdesivir-2H5, as the internal standard. Chromatographic separation was achieved on a Phenomenex® Synergi™ HPLC Fusion-RP (100 × 2 mm, 4 µm) column by gradient elution. Excellent accuracy and precision (<5.2% within-run variations and. <9.8% between-run variations) were obtained over the range of 0.5-5000 ng/mL. The assay met the FDA Bioanalytical Guidelines for selectivity and specificity, and low inter-matrix lot variability (<2.7%) was observed for extraction efficiency (77%) and matrix effect (123%) studies. Further, stability tests showed that the analyte does not degrade under working conditions, nor during freezing and thawing processes.


Subject(s)
Adenosine Monophosphate/analogs & derivatives , Alanine/analogs & derivatives , Antiviral Agents/blood , COVID-19 Drug Treatment , Drug Monitoring/methods , Tandem Mass Spectrometry/methods , Adenosine Monophosphate/blood , Alanine/blood , Chromatography, High Pressure Liquid/economics , Chromatography, High Pressure Liquid/methods , Drug Monitoring/economics , Female , Humans , Limit of Detection , Male , Tandem Mass Spectrometry/economics
SELECTION OF CITATIONS
SEARCH DETAIL